Conditions
Select the category you are interested in and below you will see the description of the work and the cost
| Service Type | Scope of Work | Price |
|---|---|---|
| Maintenance | ||
| Indoor Unit Cleaning with Disassembly 7 000–12 000 BTU | Complete disassembly and high-pressure cleaning of internal components using professional chemicals; photo documentation provided if required. | 200₾ |
| Indoor Unit Cleaning with Disassembly 12 001–24 000 BTU | Complete disassembly and high-pressure cleaning of internal components using professional chemicals. | 250₾ |
| Indoor Unit Cleaning with Disassembly from 24 001 BTU | Complete disassembly and high-pressure cleaning of internal components using professional chemicals. | 350₾ |
| Ducted Air Conditioner Indoor Unit Cleaning | Cleaning of the indoor unit in the ceiling void without dismantling the ceiling, regardless of capacity. | 400₾ |
| Outdoor Unit Washing up to 12 000 BTU | High-pressure washing of the outdoor unit without removing it from the brackets. | 200₾ |
| Outdoor Unit Washing 12 001–18 000 BTU | High-pressure washing of the outdoor unit without removing it from the brackets. | 250₾ |
| Outdoor Unit Washing 18 001–24 000 BTU | High-pressure washing of the outdoor unit without removing it from the brackets. | 300₾ |
| Outdoor Unit Washing from 24 001 BTU | High-pressure washing of the outdoor unit without removing it from the brackets. | 350₾ |
| Service Work | Inclusions | Price |
|---|---|---|
| Split System Installation | ||
| Standard Installation (Up to 3.5 kW) | Wall drilling (52/400 mm), bracket mounting, indoor unit plate mounting (up to 2.5m), connection, evacuation, and commissioning. | 400₾ |
| Standard Installation (3.6 – 5.0 kW) | Full standard installation service for medium-capacity systems. | 500₾ |
| Standard Installation (5.1 – 7.5 kW) | Full standard installation service for high-capacity systems. | 600₾ |
| Standard Installation (7.6 – 10.0 kW) | Full standard installation service for light commercial systems. | 700₾ |
| Condensate Pump Installation | Mounting of the drainage pump where natural gravity flow is not possible. | 200₾ |
| System Decommissioning | Dismantling of existing equipment. 50% discount when ordered with a new installation. | 200₾ |
| Outdoor Unit Mounting (Standalone) | ||
| Outdoor Unit Mounting (Up to 3.5 kW) | Installation on existing or new brackets/base. | 200₾ |
| Outdoor Unit Mounting (3.6 – 5.0 kW) | Mounting for medium-capacity outdoor units. | 250₾ |
| Outdoor Unit Mounting (5.1 – 7.5 kW) | Mounting for high-capacity outdoor units. | 300₾ |
| Multi-Split Outdoor Unit (Up to 10 kW) | Installation on brackets or floor base. | 500₾ |
| Multi-Split Outdoor Unit (Over 10 kW) | Installation of high-performance multi-split outdoor units. | from 600₾ |
| Indoor Unit Mounting (Standalone) | ||
| Indoor Unit Mounting (Up to 3.5 kW) | Wall mounting on a prepared surface. | 250₾ |
| Indoor Unit Mounting (3.6 – 5.0 kW) | Wall mounting for medium-capacity units. | 300₾ |
| Indoor Unit Mounting (5.1 – 7.5 kW) | Wall mounting for high-capacity units. | 350₾ |
| Additional Services | ||
| Multi-Split Commissioning | System evacuation, parameter configuration, and multi-indoor unit testing. | 250₾ |
| High-Altitude Works | Use of climbing gear, cranes, or specialized ladders for difficult access. | from 300₾ |
| Service Type | Scope of Work | Price |
|---|---|---|
| Diagnostics | ||
| Residential Air Conditioner Diagnostics | Pressure check, testing of electronic components, refrigerant line tightness, inspection of drainage, fans, and compressor. Identification of the fault cause. | 100₾ |
| Indoor Unit Control Board Diagnostics (Service Center, Board Removal Required) | Inspection, testing, and fault detection of the indoor unit electronic control board. | 150₾ |
| Inverter Outdoor Unit Control Board Diagnostics (Service Center, Board Removal Required) | Diagnostics of inverter power and control electronics, including inspection of IPM modules, drivers, sensors, and power supply circuits. | 250₾ |
| Technician Site Visit in Tbilisi (Central Districts) | Site visit and diagnostics without repair work (Saburtalo, Vake, Vera, Chugureti, Mtatsminda, Avlabari, Sololaki). | 100₾ |
| Technician Site Visit in Tbilisi (Up to 10 km from City Center) | Site visit and diagnostics without repair work for remote districts. | 150₾ |
| Service Type | Scope of Work | Price |
|---|---|---|
| Electronics Repair | ||
| Start Capacitor Replacement | Replacement of the compressor start capacitor. Inspection of the starting circuit. | 200₾ |
| Non-Inverter (On/Off) Air Conditioner Electronics Repair | Fault diagnostics, control board restoration, repair of power supply and control circuits. | 250₾ |
| Inverter Air Conditioner Electronics Repair | Repair of the indoor unit control board of an inverter air conditioner. | 550₾ |
| Outdoor Unit Control Board Repair (Inverter) | Repair of the power control board, restoration of IPM modules, drivers, MOSFET/IGBT components, voltage regulators, and feedback circuits. | 300–700₾ |
| Removal of the control board of an on/off air conditioner for diagnostics and repair | Disassembly of the indoor unit to remove the control board with power and interconnection wiring disconnected | 100₾ |
| Service Work | Description | Price |
|---|---|---|
| Leak Repair & System Preparation | ||
| Connection Re-flaring | Leak elimination: copper pipe preparation and creation of a new cone connection (flaring). | 100₾ |
| Brazing (6mm - 12mm) | Brazing copper pipes using MAPP gas and solder. Minimum labor cost. Covers 1-2 joints as needed. | 100₾ |
| Brazing (16mm - 22mm) | Brazing copper pipes using MAPP gas and solder. Minimum labor cost. Covers 1-2 joints as needed. | 200₾ |
| System Evacuation | Process of removing air and moisture from the circuit using a deep vacuum pump. | 150₾ |
| Nitrogen Pressure Test (N2) | Testing the system with high-pressure nitrogen to detect micro-leaks. | 300₾ |
| R410A Refill (Refrigerant Included) | ||
| R410A Refill (up to 3.5 kW) | Refilling the system with R410A refrigerant to factory standards using scales. | 250₾ |
| R410A Refill (3.6 – 5.0 kW) | R410A refill for medium-capacity systems. | 300₾ |
| R410A Refill (5.1 – 7.5 kW) | R410A refill for high-capacity semi-industrial units. | 350₾ |
| R32 Refill (Refrigerant Included) | ||
| R32 Refill (up to 3.5 kW) | Precision refilling of inverter systems with R32 refrigerant by weight. | 300₾ |
| R32 Refill (3.6 – 5.0 kW) | R32 refill for modern medium-capacity split systems. | 350₾ |
| R32 Refill (5.1 – 7.5 kW) | R32 refill for high-performance units. | 400₾ |
| Service Type | Scope of Work | Price |
|---|---|---|
| Refrigerant Line Installation | ||
| Refrigerant Line Installation 6/10 (Surface-Mounted, up to 2 Bends) | Installation of the refrigerant line, signal and power cables, thermal insulation, wrapping, and fastening. | 100₾/m |
| Refrigerant Line Installation 6/10 (Chased, up to 2 Bends) | Installation of the refrigerant line inside wall chases (brick/concrete), including cables, insulation, wrapping, and fastening. | 120₾/m |
| Refrigerant Line Installation 6/12 (Surface-Mounted, up to 2 Bends) | Installation of the refrigerant line, signal and power cables, thermal insulation, wrapping, and fastening. | 150₾/m |
| Refrigerant Line Installation 6/12 (Chased, up to 2 Bends) | Installation inside wall chases (brick/concrete), including the refrigerant line, cables, insulation, and wrapping. | 180₾/m |
| Refrigerant Line Installation 6/16 (Surface-Mounted, up to 2 Bends) | Installation of the 6/16 refrigerant line, signal and power cables, thermal insulation, wrapping, and fastening. | 180₾/m |
| Refrigerant Line Installation 6/16 (Chased, up to 2 Bends) | Installation of the 6/16 line inside wall chases (brick/concrete), including cables, insulation, and wrapping. | 200₾/m |
| Refrigerant Line Installation 10/20 (Surface-Mounted, up to 2 Bends) | Installation of the heavy-duty 10/20 refrigerant line with power and signal cables, insulation, and wrapping. | 200₾/m |
| Refrigerant Line Installation 10/20 (Chased, up to 2 Bends) | Installation of the 10/20 line inside wall chases with a full set of cables, insulation, and wrapping. | 220₾/m |
| Brick Wall Chasing | Wall chasing for refrigerant lines, including dust extraction. | 75₾ |
| Concrete Wall Chasing | Concrete wall chasing with vacuum dust removal. | 95₾ |
| Drain Line Installation | Installation of a drainage hose without insulation, with minimal fastening. | 10₾ |
| Polypropylene Pipe Installation | Welding of polypropylene pipes for condensate drainage. | 60₾ |
| Service Type | Scope of Work | Price |
|---|---|---|
| Diamond Drilling | ||
| Diamond Drilling 52 mm (Brick) | 52 mm diameter hole, drilling depth up to 400 mm. Drilling with dust extraction. Construction cleanup after completion. | 150₾ |
| Diamond Drilling 52 mm (Concrete) | 52 mm diameter hole, drilling depth up to 400 mm. Drilling with dust extraction. Construction cleanup after completion. | 200₾ |
| Diamond Drilling 108 mm (Brick) | 108 mm diameter hole, drilling depth up to 400 mm. Drilling with dust extraction. Construction cleanup after completion. | 190₾ |
| Diamond Drilling 108 mm (Concrete) | 108 mm diameter hole, drilling depth up to 400 mm. Drilling with dust extraction. Construction cleanup after completion. | 250₾ |
| Diamond Drilling 132 mm (Brick) | 132 mm diameter hole, drilling depth up to 400 mm. Drilling with dust extraction. Construction cleanup after completion. | 230₾ |
| Diamond Drilling 132 mm (Concrete) | 132 mm diameter hole, drilling depth up to 400 mm. Drilling with dust extraction. Construction cleanup after completion. | 300₾ |
| Diamond Drilling 152 mm (Brick) | 152 mm diameter hole, drilling depth up to 400 mm. Drilling with dust extraction. Construction cleanup after completion. | 270₾ |
| Diamond Drilling 152 mm (Concrete) | 152 mm diameter hole, drilling depth up to 400 mm. Drilling with dust extraction. Construction cleanup after completion. | 350₾ |
| Service Type | Scope of Work | Price |
|---|---|---|
| Air Breather Installation | ||
| Standard Air Breezer Installation 132 mm (Brick) | Diamond drilling of a 132 mm hole in a brick wall, drilling depth up to 400 mm. Installation and insulation of the air duct, sealing. Installation of the exterior grille and wall-mounted air breather. Connection to a pre-installed power supply. Operational check and basic cleanup after installation. | 250 ₾ |
| Standard Air Breezer Installation 132 mm (Concrete) | Same scope of work as the previous service. | 400 ₾ |
| Standard Air Breezer Installation 152 mm (Brick) | Same scope of work as the previous service. | 350 ₾ |
| Standard Air Breezer Installation 152 mm (Concrete) | Same scope of work as the previous service. | 450 ₾ |
| Additional Services | ||
| Air Breezer Installation into Existing Opening | Use of an existing opening (132–152 mm) without drilling. Inspection of the duct, installation of air duct/insulation if required, installation of the grille and air breather, connection and testing. | 150–200 ₾ |
| Power Supply Connection for Air Breather (From Nearest Point) | Cable routing in a cable duct or surface-mounted along the wall, connection to an existing electrical line, installation of a socket or junction box on site. No wall chasing included. | 100–150 ₾ |
| Air Breezer Installation With Partially Concealed Wiring | Local wall chasing for cable routing in the installation area, cable installation, wall restoration, air breather installation and connection. | 150–200 ₾ |
| Second Air Breezer Installation During the Same Visit | Discount applied when installing a second and each additional air breather within the same site and during the same visit. | –50 ₾ from the base price for each additional unit |
| Service Type | Scope of Work | Price |
|---|---|---|
| Cold Room Installation (Full Scope of Work) | ||
| Cold Room 3–5 m³ | Assembly of panels and locking joints, sealing, monoblock installation, connection to pre-installed power supply, sensor installation, test run. | 600 ₾ |
| Cold Room 5–8 m³ | Assembly of panels and locking joints, sealing, monoblock installation, connection to pre-installed power supply, sensor installation, test run. | 800 ₾ |
| Cold Room 8–12 m³ | Assembly of panels and locking joints, sealing, monoblock installation, connection to pre-installed power supply, sensor installation, test run. | 1100 ₾ |
| Refrigeration Equipment Installation up to 12 000 BTU | Low-capacity monoblock or split system: mounting, refrigerant line, drainage, power supply, controls, test startup. | from 600 ₾ |
| Refrigeration Equipment Installation 12 001–24 000 BTU | Medium-capacity unit: refrigerant line, insulation, cabling, sensor connection, vacuuming, system setup. | from 800 ₾ |
| Refrigerant Line Installation (Surface-Mounted) | ||
| Refrigerant Line 6/10 | 6 + 10 mm copper pipes, thermal insulation, signal cable, 5×1.5 power cable, wrapping, fasteners. | 100 ₾/m |
| Refrigerant Line 6/12 | 6 + 12 mm copper pipes, thermal insulation, signal cable, 5×1.5 power cable, wrapping. | 150 ₾/m |
| Refrigerant Line 6/16 | 6 + 16 mm copper pipes, thermal insulation, signal cable, 5×1.5 power cable, wrapping. | 180 ₾/m |
| Refrigerant Line 10/20 | 10 + 20 mm copper pipes, thermal insulation, signal cable, 5×2.5 power cable, wrapping. | 200 ₾/m |
| Drain Pipe 16 mm | Surface-mounted drain installation with minimal fasteners. | 20 ₾/m |
| Polypropylene Pipes (Welding) | Surface-mounted polypropylene pipes for drainage. | 60 ₾/m |
| Consumables | Description | Price |
|---|---|---|
| Refrigerant Line Sets (Pre-Assembled Copper Lines) | ||
| Line Set 6/10 | Copper pipes 6 mm + 10 mm, thermal insulation, signal cable, 5×1.5 power cable, wrapping. | 70 ₾/m |
| Line Set 6/12 | Copper pipes 6 mm + 12 mm, thermal insulation, signal cable, 5×1.5 power cable, wrapping. | 120 ₾/m |
| Line Set 6/16 | Copper pipes 6 mm + 16 mm, thermal insulation, signal cable, 5×1.5 power cable, wrapping. | 150 ₾/m |
| Line Set 10/20 | Copper pipes 10 mm + 20 mm, thermal insulation, signal cable, 5×2.5 power cable, wrapping. | 170 ₾/m |
| Other Consumables | ||
| Wall mounting bracket for air conditioner 7/9/12/18 | Bracket for small to medium-capacity outdoor units. | 50 ₾ |
| Wall mounting bracket for air conditioner 24/32/42 | Reinforced bracket for medium and large outdoor units. | 70 ₾ |
| Drain Hose 16 mm | Flexible drain hose for condensate removal. | 5 ₾/m |
| Wrapping Tape (Roll) | Insulating wrapping tape for refrigerant lines. | 10 ₾ |
| Multilayer Pipe 16 mm or PP Pipe 20 mm | For condensate drainage. Welding/jointing not included. | 5 ₾/m |
| Fastener Kit | Fasteners for indoor and outdoor units (anchors, screws, washers). | 7 ₾ |
Copyright © AirFixer